The depth of discharge in conjunction with the battery capacity is a fundamental parameter in the design of a battery bank for a PV system, as the energy which can be extracted from the battery is found by multiplying the battery capacity by the depth of discharge. Batteries are rated either as deep-cycle or shallow-cycle. . Over time, battery capacity degrades due to sulfation of the battery and shedding of active material. The degradation of battery capacity depends most strongly on the interrelationship between. . The production and escape of hydrogen and oxygen gas from a battery cause water loss and water must be regularly replaced in lead acid. . Depending on which one of the above problems is of most concern for a particular application, appropriate modifications to the basic. . Lead acid batteries typically have coloumbic efficiencies of 85% and energy efficiencies in the order of 70%. [pdf]
The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. This is because lead acid batteries age / wear out faster if you deep discharge them. The most important lesson here is this:
A deep-cycle lead acid battery should be able to maintain a cycle life of more than 1,000 even at DOD over 50%. Figure: Relationship between battery capacity, depth of discharge and cycle life for a shallow-cycle battery. In addition to the DOD, the charging regime also plays an important part in determining battery lifetime.
It turns out that the usable capacity of a lead acid battery depends on the applied load. Therefore, the stated capacity is actually the capacity at a certain load that would deplete the battery in 20 hours. This is concept of the C-rate. 1C is the theoretical one hour discharge rate based on the capacity.
Personally, I always make sure that anything connected to a lead acid battery is properly fused. The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. This is because lead acid batteries age / wear out faster if you deep discharge them.
So many lead acid batteries are 'murdered' because they are left connected (accidentally) to a power 'drain'. No matter the size, lead acid batteries are relatively slow to charge. It may take around 8 - 12 hours to fully charge a battery from fully depleted. It's not possible to just dump a lot of current into them and charge them quickly.
Lead acid batteries should never stay discharged for a long time, ideally not longer than a day. It's best to immediately charge a lead acid battery after a (partial) discharge to keep them from quickly deteriorating.

Lead–acid batteries lose the ability to accept a charge when discharged for too long due to sulfation, the crystallization of . They generate electricity through a double sulfate chemical reaction. Lead and lead dioxide, the active materials on the battery's plates, react with in the electrolyte to form . The lead sulfate first forms in a finely divided, state and easily reverts to lead, lead dioxide, and sulfuric acid when the battery rech. The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. [pdf]
The lead acid battery maintains a strong foothold as being rugged and reliable at a cost that is lower than most other chemistries. The global market of lead acid is still growing but other systems are making inroads. Lead acid works best for standby applications that require few deep-discharge cycles and the starter battery fits this duty well.
Personally, I always make sure that anything connected to a lead acid battery is properly fused. The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. This is because lead acid batteries age / wear out faster if you deep discharge them.
It turns out that the usable capacity of a lead acid battery depends on the applied load. Therefore, the stated capacity is actually the capacity at a certain load that would deplete the battery in 20 hours. This is concept of the C-rate. 1C is the theoretical one hour discharge rate based on the capacity.
The common rule of thumb is that a lead acid battery should not be discharged below 50% of capacity, or ideally not beyond 70% of capacity. This is because lead acid batteries age / wear out faster if you deep discharge them. The most important lesson here is this:
Proper temperature management, such as insulation or ventilation during cold storage or hot operation, would ensure optimum lead acid battery performance and prolong its operational life. 11. JIS Standard
It's best to immediately charge a lead acid battery after a (partial) discharge to keep them from quickly deteriorating. A battery that is in a discharged state for a long time (many months) will probably never recover or ever be usable again even if it was new and/or hasn't been used much.

The most notable difference between lithium iron phosphate and lead acid is the fact that the lithium battery capacity is independent of the discharge rate. The figure below compares the actual capacity as a percentage of the rated capacity of the battery versus the discharge rate as expressed by C (C equals the. . Lithium delivers the same amount of power throughout the entire discharge cycle, whereas an SLA’s power delivery starts out strong, but dissipates. The constant power advantage of lithium is shown in the graph below. . Charging SLA batteries is notoriously slow. In most cyclic applications, you need to have extra SLA batteries available so you can still use your. . Cold temperatures can cause significant capacity reduction for all battery chemistries. Knowing this, there are two things to consider when evaluating a battery for cold temperature use: charging and discharging. A lithium. . Lithium’s performance is far superior than SLA in high temperature applications. In fact, lithium at 55°C still has twice the cycle life as SLA does at room temperature. Lithium will. [pdf]