For all methods of transport the U.S. legal requirements are laid down in the Code of Federal Regulations (CFR 173.159) which state: 1. Batteries should be individually wrappedso that there is no chance of the terminals coming into contact with any external material or other battery terminals in the same package –. . Non-spillable lead acid batteries (those that use Gel or Absorbent Glass Matt technology) require the same packaging as those filled with acid. . Carriers will usually require these to be drained of acid and enclosed in an acid proof liner. Some may state that the battery is also covered with soda ash (which neutralizes acid).. . Just because your lead acid battery won’t do what you want it to do like start and engine does not mean that it is completely dead. Shorting out the. [pdf]
UN specification packaging such as 4G fiberboard boxes, various types of drums, and wooden boxes are all compliant to ship lead acid batteries per the 49CFR. If you are shipping by air, a leakproof liner is also a requirement as well.
Similarly, the IMDG code sets out similar requirements at Packing instruction P801 when you are shipping internationally by Sea. Using UN packaging would also be acceptable to ship lead acid batteries within Canada as well as by Sea internationally. If you are shipping internationally by air, we would look in IATA at Packing instruction 870.
The transportation of lead acid batteries by road, sea and air is heavily regulated in most countries. Lead acid is defined by United Nations numbers as either: The definition of ‘non-spillable’ is important. A battery that is sealed is not necessarily non-spillable.
Per the 49CFR 173.159, lead acid batteries must be packaged in a manner to prevent a dangerous evolution of heat and short circuits. This would include, when practicable, packaging the battery in fully enclosed packaging made of non-conductive material, and ensuring terminals aren’t exposed.
Let’s take a look at the various domestic and international regulations. For the purpose of this blog, we will be examining Lead Acid Batteries classified as UN2794 which are Batteries, wet, filled with acid. Per the 49CFR 173.159, lead acid batteries must be packaged in a manner to prevent a dangerous evolution of heat and short circuits.
First things first, unless there is an exception of some sort, a class 8 corrosive label and a class 8 placard would be required when shipping lead acid batteries. But when it comes to packaging, there is a bit more that needs to be discussed. Let’s take a look at the various domestic and international regulations.

When purchasing a battery, you will see a series of numbers and letters in the name. These numbers and letters are the BCI group size of the battery. BCI stands for Battery Council International. This is a trade association that includes manufacturers, recyclers, distributor, and retailer organizations that supply original and after. . First, each vehicle comes with a specific battery tray size, whether it’s a car, truck, SUV, commercial vehicle, boat, recreational vehicle, or other vehicles. It is important to choose a. . BCI is the most common system used to classify battery group sizes. The following battery group size chart explains the most common BCI battery groups and their specifications. . The BCI designationsinclude the group definition, dimensions, measurements, types, sizes, and other characteristics. The battery conversions chart can help you to cross-reference battery sizes, but it is also useful to understand the. . When choosing a battery, it is important to use the ones that are recommended by the manufacturer for your make and model of the vehicle. The easiest. [pdf]
The dimensions of a Group 35 battery are: The average group 35 battery weighs 30lbs (13kg). You can reduce this by 50% with a lithium phosphate equivalent. Group 35 are mainly built as starting batteries to start vehicle engines. Or as dual purpose marine used for a mix of starting and cyclical application. You won’t find deep cycle group 35.
You have a few options when looking for the right battery for your car or truck. Group 29 and group 31 batteries are designed for automotive applications. But there are some key differences between them that you need to be aware of before making a purchase. But what exactly are these groups?
Group 31 batteries are categorized primarily by their size, not by their power, even though power affects energy production. The dimensions of Group 31 batteries are 13 inches long, 6 13/18 inches wide, and 9 7/16 inches tall. Group 31 batteries are larger than Group 29NF batteries, as well as being shorter and wider than Group 29H batteries.
This adaptability, combined with robust performance metrics, positions Group 35 batteries as a top choice for both everyday users and professionals alike. Group 35 batteries are integral components in automotive and various other applications, known for their reliable performance and standardized dimensions.
The dimensions of Group 31 batteries are 13 inches long, 6 13/18 inches wide, and 9 7/16 inches tall. Group 31 batteries are larger than Group 29NF batteries, as well as being shorter and wider than Group 29H batteries. Group 34 batteries are medium-size and powerful that provide 750-900 CCA, 100-145 minutes of reserve capacity.
The application of the batteries is the same in certain cases. You’ll find both as starting and dual purpose marine. Group 35 deep cycle batteries are rare and more easy to find as group 34. So check the application carefully before making a replacement.

Yes. Any lead acid or AGM battery can be replaced with a lithium battery. A more specific question would be, ‘What is the best type of lithium better to use to replace lead acid/AGM for a given application?’ There. . Converting 12v Powerwall / Off Grid to LithiumThe first step in upgrading a 12-volt lead acid battery to lithium is to choose the cell chemistry and co. . Replacing lead acid in a scooter is easy. This is because scooters are generally powered by just a single 12-volt lead acid battery with a capacity of about 8 amp hours or so. Lithi. . When replacing a golf car lead acid or AGM battery with a lithium-ion battery, there are many options. Golf carts are not high-speed, high-power vehicles. This means that the battery r. . Charging Lithium Converted DevicesLead acid batteries require a simple constant voltage charge to the battery while lithium ion chargersuse 2 phases; constant current and then. [pdf]
If you are upgrading a home battery bank to lithium and you already have a modern charge controller, the process could be as simple as installing the new batteries and flipping a switch. If, however, you are replacing a lead acid/AGM battery with lithium in a vehicle or RV, then you must consider the capabilities of the alternator.
Yes, you can swap lead-acid batteries with lithium-ion ones in many cases. But, you must check if the system fits the new battery’s needs. This includes voltage, charging, and space. The right lithium battery, like LiFePO4 (LFP) or Lithium Nickel Manganese Cobalt (Li-NMC), ensures top performance and life.
Lead acid batteries require a simple constant voltage charge to the battery while lithium ion chargers use 2 phases; constant current and then constant voltage. Unlike lead acid batteries, Lithium-ion batteries have an extremely small capacity loss when sitting unused.
A Comprehensive Guide As the demand for efficient and reliable power storage solutions grows, many are considering the transition from traditional 12V lead acid batteries to advanced lithium-ion batteries. This shift is not merely a trend but a significant upgrade that offers various benefits.
When you switch from a lead-acid to a lithium-ion battery, knowing the voltage is key. Lithium-ion batteries, like LiFePO4, have different voltages than lead-acid ones. For 12V systems, a 4S LiFePO4 setup can match lead-acid voltages well. But for 24V or 48V systems, you have more options.
Lithium-ion batteries require a specific charging profile that is different from lead-acid batteries. You will need to purchase a charger that is designed to work with lithium-ion batteries. Make sure that the charger you choose is compatible with the voltage and capacity of your new battery.
We are dedicated to providing reliable and innovative energy storage solutions.
From project consultation to delivery, our team ensures every client receives premium quality products and personalized support.