Sensor angle and tilt shall match exactly to the array it is referencing. Ensure there is no additional shading on the sensor (e.g. from the module frame). Ensure the mounting location is. . The sensors should be checked once a year for damage, contamination and correct fitting. . Connect the sensor to the Commercial Gateway as specified in the following table: . It is possible to extend the original shielded cables if needed, up to the following length (meter) of additional shielded cabling: [pdf]
Locally powered 4-wire sensor transmitters are popular in applications where the wires must run long distances and the sensor consumes >4mA, preventing the use of a 2-wire transmitter. A common example is electromagnetic flow metering. Figure 1: Output-isolated 4-wire sensor transmitter with local power supply
The meter is connected to an RS485 port of one of the inverters. If the inverter has a second RS485 port, use this port to connect between the inverters. If the inverter has only one RS485 port, use an RS485 Plug-In (available from SolarEdge) or ZigBee communication between the inverters.
Therefore, you can use a simple current-sink topology like the one shown in Figure 2. You could also use a current-source topology, but that would require a two-stage design similar to those found in 3-wire transmitters. Figure 2: 4-wire sensor transmitter output stage design
Install under a cover to protect the sensor from direct exposure to sunlight, precipitation and meltwater. Glue the sensor element (aluminum block) directly to the module back sheet. The surface must be dry, clean and degreased before affixing the element to the surface.
The ground connection should be made using a heavy gauge wire and kept as short as possible. If the cable between the SolarEdge device and the protection device must be longer than 1m/3.3 ft., a copper strap or a braided cable intended for grounding purposes must be used for the protection device to be effective.
Environmental sensors are used to monitor a site’s irradiance, temperature and wind conditions and calculate performance ratio (PR). Sensors connect to the SolarEdge Commercial Gateway and the measurements are displayed in the SolarEdge monitoring server. Up to three sensors can be connected to a single Commercial Gateway.
We are dedicated to providing reliable and innovative energy storage solutions.
From project consultation to delivery, our team ensures every client receives premium quality products and personalized support.